Abbott News
FDA Approves Abbott's XIENCE(TM) V Drug Eluting Stent
ABBOTT PARK, Ill.,
"XIENCE V represents an important treatment advance for the estimated 13 million people in
The XIENCE V drug coated stent is used to treat coronary artery disease by propping open a narrowed or blocked artery and releasing the drug, everolimus, in a controlled manner to prevent the artery from becoming blocked again following a stent procedure. Coronary artery disease occurs when plaque build- up narrows the arteries and reduces blood flow to the heart, which can lead to chest pain or a heart attack.
"XIENCE V was designed to improve safety and efficacy compared to earlier generation stents. The long-term clinical data from two studies performed in both
Clinical Data Supporting XIENCE V
The robust clinical program for XIENCE V includes long-term data from a total of 1,362 patients enrolled in the SPIRIT FIRST, SPIRIT II and SPIRIT III trials, as well as continued access and post-approval programs that will enroll more than 14,000 XIENCE V patients.
The FDA approved XIENCE V based, in large part, on superior results from the 1,002 patient SPIRIT III U.S. pivotal clinical trial, in which XIENCE V demonstrated statistical superiority to TAXUS on the study's primary endpoint of in-segment late loss (vessel renarrowing) at eight months, with a statistically significant 50 percent reduction (mean, 0.14 mm for XIENCE V vs. 0.28 mm for TAXUS). XIENCE V also demonstrated statistical non-inferiority to TAXUS in the co-primary endpoint of target vessel failure (TVF, cardiac events related to the stented vessel) at nine months, with an observed 20 percent reduction (7.2 percent for XIENCE V vs. 9.0 percent for TAXUS). TVF is a composite clinical measure of safety and efficacy outcomes defined as cardiac death, heart attack (myocardial infarction or MI) or target vessel revascularization (TVR).
In
— A 45 percent reduction in the risk of major adverse cardiac events (MACE) compared to TAXUS (7.3 percent for XIENCE V vs. 12.8 percent for TAXUS, p-value=0.004)*. MACE is an important composite clinical measure of safety and efficacy outcomes for patients, defined as cardiac death, heart attack (MI) or ischemia-driven target lesion revascularization (TLR, repeat procedures driven by lack of blood supply).
— A 32 percent reduction in the risk of TVF compared to TAXUS (10.7 percent for XIENCE V vs. 15.4 percent for TAXUS, p-value=0.04)*.
— Low rates of stent thrombosis between one and two years, defined as very late stent thrombosis, per Academic Research Consortium (ARC) definition of definite/probable stent thrombosis (0.3 percent for XIENCE V and 1.0 percent for TAXUS) and per the SPIRIT III protocol (0.2 percent for XIENCE V and 1.0 percent for TAXUS). The ARC definition of late stent thrombosis was developed to eliminate variability in the definitions across various drug eluting stent trials.
"Today's approval of XIENCE V is a reflection of Abbott's ongoing commitment to bring innovation-driven, leading-edge medical technologies to the people who need them," added Capek. "With one of the largest, most seasoned vascular sales forces in
More About XIENCE V
XIENCE V is built upon Abbott's market-leading bare metal stent, the MULTI-LINK VISION(R) Coronary Stent System. The VISION platform is designed to facilitate ease of delivery, making it easier for physicians to maneuver the stent and treat the diseased portion of the artery.
The XIENCE V drug coated stent will be available on both over-the-wire (OTW) and rapid exchange (RX) delivery systems. Rapid exchange is the most widely used type of delivery system because it provides physicians additional flexibility to work as single operators during stent procedures.
XIENCE V was launched in
Abbott also supplies a private-label version of XIENCE V to Boston Scientific called the PROMUS(TM) Everolimus-Eluting Coronary Stent System. PROMUS is designed and manufactured by Abbott and supplied to Boston Scientific as part of a distribution agreement between the two companies.
Everolimus, developed by Novartis Pharma AG, is a proliferation signal inhibitor, or mTOR inhibitor, licensed to Abbott by Novartis for use on its drug eluting stents. Everolimus has been shown to inhibit in-stent neointimal growth in the coronary vessels following stent implantation, due to its antiproliferative properties.
Additional information about XIENCE V, including important safety and effectiveness information, is available online at http://www.xiencev.com.
About Abbott Vascular
Abbott Vascular, a division of Abbott, is one of the world's leading vascular care businesses. Abbott Vascular is uniquely focused on advancing the treatment of vascular disease and improving patient care by combining the latest medical device innovations with world-class pharmaceuticals, investing in research and development and advancing medicine through training and education. Headquartered in
About Abbott
Abbott is a global, broad-based health care company devoted to the discovery, development, manufacture and marketing of pharmaceuticals and medical products, including nutritionals, devices and diagnostics. The company employs more than 68,000 people and markets its products in more than 130 countries.
Abbott's news releases and other information are available on the company's Web site at http://www.abbott.com.
*Event rates are based on Kaplan-Meier estimates; p-values are for descriptive purposes only.
EDITORS NOTE: Additional background information, including broadcast- quality video, animation and images, are available to members of the media through the XIENCE V media kit at http://www.xiencemediakit.com.
SOURCE Abbott